Tuesday, November 24, 2009

CO2 Sublimation


A client inquired why a CO2 vessel can be full by weight, but no product will come out. They mentioned that they'd been able to feed NF Nitrogen into the vessel and then get CO2 out.


"I think the principle issue here is one of pressure. CO2 is one of a few substances that go straight from the gas to solid phase and vice versa at atmospheric pressure. The only way to keep it in liquid form is to maintain adequate pressure as shown on this chart http://www.school-for-champions.com/science/dry_ice.htm.

We’ve found it necessary to use pressure to convert the sold back to a liquid once CO2 turns to dry ice (solid) due to a drop in pressure below the level needed to stay as a liquid. This can be done a number of ways and the addition of N2 as you have done is one. The key in your approach is to be certain that flow is tightly controlled and there are reliefs on all hoses and other trap points to prevent rupturing lines or tanks. Complete removal of all CO2 from the vessel can be pretty time consuming and take several days to accomplish. Once all CO2 is removed from the vessel, it is suggested that you use liquid nitrogen to test all functions of the vessel and perform a thorough leak check.

If you have a leak in a pressure building line or regulator, for instance, you get exactly the opposite result from the one desired when you open the PB isolation valve. The same can occur due to a leak in a valve stem or packing. When the valve is opened and a resultant leak occurs pressure will drop and then dry ice will form."

Friday, November 20, 2009

AWS Fabtech 2009

Bob Burg and John David Mann provide an interesting perspective in a passage of "The Go-Giver" where The Chairman explains, "Most of us have grown up seeing the world as a place of limitation rather than a place of inexhaustible treasures. A world of competition rather than one of co-creation."

The great joy of this year's Fabtech show was the incredible number of "Co-Creators" we had the pleasure of visiting with. People from all over the U.S. and the world had incredibly inspiring success stories to share... both past and in the making. All sorts of industries (both cryogenics related and not) were included. And- there was no regard for the actual location. People from Iowa, Michigan, Alabama, Texas, New York, Eastern Europe, Latin American, Asia and anywhere else you could imagine all had great experiences and enthusiasm to share. It was a cup we gladly drank from and are still savoring.

Most assuredly, people all over had confronted issues this year, but the prevailing attitude was that it was just another challenge like so many before.

All I can really say is THANK YOU to everyone who made this last week so enjoyable. It will be a big part of this year's Thanksgiving celebration remembrances.

Tuesday, November 17, 2009

4L DOT Standards- Size by Default


A client called today with an issue related to a 4L-DOT cryogenic liquid vessel. At question was the size of the vessel and the concern was that the vessel was over 119 gallons.


It will be interesting to see how their issue is resolved since according to the 49CFR Sec. 178.57 Specification 4L welded insulated cylinders. "(a) Type, size, service pressure, and design service temperature. A DOT 4L cylinder is a fusion welded insulated cylinder with a water capacity (nominal) not over 1,000 pounds water capacity and a service pressure of at least 40 but not greater than 500 psig......"


Since water weighs 8.3453 pounds per gallon this means that the absolute maximum capacity of a 4L vessel would be 119.83 gallons. Most vessels have some head space allowance so nominal capacities for the largest 4L cryogenic liquid cylinders tend to be under 119 gallons. But- depending on the specific vessel, the water capacity could technically be 119 point something, but under 120 gallons.


So- like I said, it will be interesting to see what comes of their question. As always- any comments on this are welcomed.


Monday, November 16, 2009

Cryogenic Liquid Cylinder Hot Fill


A recent call (summarized):

"Our client purchased some new cryogenic liquid cylinders, filled them and put them into service. They seem to be venting excessively and they are concerned. Can you crack the inner vessel of a new cryogenic liquid cylinder if you improperly fill it? Is there a Hot Fill Procedure that should be followed to avoid excessive venting?"

I've never heard of a cryogenic liquid cylinder with a stainless inner vessel actually cracking..... even after sitting out in Houston or Phoenix sun for awhile. It would be interesting to hear from an engineering or physics standpoint just how much temperature differential a vessel can tolerate, but it is not something that is a cause for concern in everyday applications.

As for Hot Fill Procedures- Yes. It is important to cool liquid cylinders that are new or have been sitting around "hot."

During one memorable problem solving activity a client commented that his cryogenic liquid cylinders "are not hot. They are <0 degrees F inside." True or False?

Think about a hot (400 degree) skillet used for blackening or stir frying. Throw a little water into it and see what happens. The water will flash vaporize because the skillet is nearly 200 degrees above the boiling point of water.

Go back to a cryogenic vessel that is 0 to 80 degrees F inside. Run some liquid nitrogen, oxygen or argon into it that is about -300 degrees F and you can be sure that you will get violent flashing since the vessel is 300 to 400 degrees above the boiling point of the cryogenic liquid.

There are a number of ways to cool a hot cryogenic liquid cylinder and thereby decrease the normal vaporization and consequent venting of your liquid nitrogen, oxygen or argon. A very simple one is to:

a) Open the vent;
b) Connect your source line to the vessel; Open the liquid fill line and the open the source just enough to slowly run liquid into the cryogenic cylinder;
c) Very heavy venting will occur. Keep running liquid slowly into the cryogenic cylinder until it is about 1/4 full. Shut off the fill and leave the vent open.
d) Allow the vessel to vent until the venting becomes very moderate. This can take 1-2 hours.
e) Slowly fill the vessel the rest of the way until the full weight is reached; Some more heavy venting can occur;
f) Let the vessel vent until venting is almost completely stopped; Top off the vessel if more product is needed.

Remember- Fully venting cryogenic vessels is important when filling whether the vessel is hot or not. For more notes on this you can see http://cryonews.blogspot.com/2009/09/cryogenic-liquid-cylinder-filling.html

Thursday, October 29, 2009

4L DOT Cryogenic Liquid Cylinders - Age Coding


Client X has a few dozen liquid cylinders that they are considering repairing and want to be sure that they aren’t too old to be worth the trouble. So- Their very good question:

“Is there any way to tell from the data plate what year a DOT 4L- class vessel was manufactured?”

I’ll give you what I got from some quick targeted research and will appreciate any information you might have to share with the rest of us:

TAYLOR-WHARTON- The last letter in the serial number identifies the year of manufacture.
A=1985 to H=1992
J=1993 to N=1997
P=1998 to X=2005
BB=2005 to FF=2009

UCAR- Purchased by Taylor-Wharton in 1985 so anything UCAR is 1985 or before

CHART/MVE- Beginning in 1995 the Year of Manufacture was inserted right in the middle of the serial number. So this is the most obvious… 97, 99, 02, etc. If the unit is before 1995 then the only way to know is to call the number and ask.

CSI- Purchased by Chart in 1995 (?). No defined date code system.

CYLTEC- No date code imbedded in the serial number, but virtually all are 2005 or newer.

Tuesday, October 20, 2009

Cryogenic Fill Hose Safety Reliefs- An absolute necessity


Why are safety reliefs installed on all cryogenic liquid oxygen, nitrogen, argon or carbon dioxide fill hoses?
In fact- safeties are not only to be installed on all fill hoses. They are also installed on any cryogenic line that is sealed on both sides. This is because cryogenic liquid trapped in a line will vaporize and expand exponentially creating tremendous pressure in hoses, piping or tubing. This expanding liquid nitrogen, oxygen, argon, or CO2 can easily build enough pressure to cause the line or hose to explode with great force.

This is a danger that is easily overlooked and one that is not obvious to someone without prior knowledge or training. And- it is something that can be missed by even the most experienced personnel who are hooking up a new line out of necessity or otherwise in a hurry.
Whether you are filling medical oxygen bases, transfilling liquid from one DOT4L vessel to another or otherwise filling from a bulk source it is essential to have a relief for expanding vapor. So- never forget to be sure the hose you are using to fill has a properly rated safety relief installed somewhere between the valves or other connectinos that could trap liquid.

Friday, October 16, 2009

MedTrade Day 3










Clare Ulik of Cryovations sent these photos from Day 2 that tell the tale..... lots of folk with great attitudes.
Of course.... as always... Day 3 didn't have nearly the number of people, but moods were still great. And- the reduced activity allows for some more in depth discussions so all was good.

In the world of medical liquid oxygen delivery there are obviously still opportunities for operational improvements and optimizing gains from improved efficiency. And then there is also the situation presented by those with smaller client bases. For those with 5-25 or so patients with no real expectation of growth the option of subcontracting liquid delivery can often make a lot of sense.

How is it that an Airgas Puritan Medical or a Lifegas or others can turn a profit where a smaller company can't? Consolidation.
Trying to be profitable delivering to two or three patients in a given area can be almost impossible. Add them to a route that already has 10-15 patients and all the sudden they offer a great return as all the real cost of getting into the territory has been covered and everything extra is where the real return is made. It might seem obvious, but is still not universal knowledge.

Wednesday, October 14, 2009

MedTrade Day 2

Don't talk with your hands. I've heard it many, many times and still haven't learned.

Oh, and what a great day today at MedTrade. The good news/ bad news is that we'll be back next year. It was great to see a goodly number of client friends and new friends that we would not have seen otherwise. Also encouraging was the presale of booth space for next year's show.

And then there was the neat little information tidbit related to the BPR Medical FireSafe TM device for respiratory oxygen cannulas. This link http://www.lifegas.com/files/firesafeV2.htm will get you to a little video showing how it works.

Tuesday, October 13, 2009

MedTrade Day One 2009

Color me surprised and pleasantly so.

I was told that attendance at this year's MedTrade is down significantly and would have plenty of reason to believe this is true. Nonetheless, activity today was by no means the worst I've experienced at a trade show and the quality of discussions was was superior.

The ability to really converse with people and have in-depth visits about the needs and challenges of their business is one of the collateral benefits of this year's downturn. And- people have an interest in considering options that would reduce their costs of operations. One new introduction today was eTankPro (Roger MacClellan) and he seems to be one of those businesses keyed in on really helping clients reduce costs through improved efficiencies.

And a goodly number of people that might previously have brushed past or just quickly introduced and grabbed a card had a chance to consider how maybe 3 trucks with 290 gallon vessels delivery medical liquid oxygen could be a world more productive than 5 with 119s. This was especially true for one fellow who goes 30 miles everyday to fill a 119 and then only has enough liquid to fill 8-10 patient bases. This was a real case in point for what a difference a 290 gallon UltraSeries vessel could make. Just cutting trips to the bulk fill by 50% is huge without even taking into account the ability to make 5-15 more stops per week with the larger volume of liquid and time he'd have available.

Wednesday, September 30, 2009

Cryogenic Bulk Tanks- Vacuum & Leaks (d)


The principle differences between Bulk Tank and 4L-Liquid Cylinder vacuum investigations?

A) Size and B) More parts and Penetrations

Bulk Tank size matters a great deal when it comes to the ability to conduct and effective vacuum investigation. A liquid cylinder can typically be thoroughly investigated in less than an hour. A perlite bulk tank can take weeks just to get a vacuum good enough on it to perform an effective investigation. Investigating in place will also frequently require the use of a manlift or other device to get all the way up and around the vessel seams, lift plate, etc. Add just a little breeze and it can be well nigh impossible to get a accurate investigation completed due to helium dispersal. The only answer is tenting or bagging section of the vessel which further increases the time required.

Add to Size issues related to additional parts- especially the probe tube. Probe tubes frequently leak through causing vacuums to go bad just by trying to read them. This has been true in many cases even with new probe tubes. There have also been a number of leaks in the probe tube isolation valve handles that are sometimes only present with the valve open. Then there is the vacuum lift plate used on many bulk tanks. This plate is o-ring and lube sealed by the vacuum pulled on the tank. And unlike 4L- Liquid Cylinders which have all piping run through a single head boss, bulk tanks are loaded with line penetrations. None of these issues are overly challenging for a capable investigator using helium mass spec equipment. But they do help explain why those not performing full investigations can get a good vacuum pulled on a tank and leave believing the tank is fixed.

We go back to size and semi-permanent installation. Unlike a liquid cylinder it is a huge undertaking to remove a bulk tank, send it in for vacuum investigation and restoral and reinstall. And, there is typically not a ready supply of spares to pop in place while a bulk tank is being repaired. Hence- It is almost always easiest to send 4L- Liquid Cylinders in for repair while it is frequently justifiable to perform bulk investigations in the field. Justifiable…… but often costly nonetheless making it all the more critical that the right tools and right people are used.

Monday, September 28, 2009

Cryogenic Bulk Tanks- Vacuum & Leaks (c)

How do bulk cryogenic vacuum investigations differ from liquid cylinder vacuum investigations?

The principle differences relate to the size of the vessels and the more permanent nature of bulk cryogenic tank installations. There is also an issue with added penetrations and connections on a bulk tank which mean more potential leak points. There are also a couple of other nuisances related to probe tubes, lift plates, vacuum valve and perlite insulation. First- The principles of helium mass-spec leak detection are the same for almost all double-walled, vacuum-insulated cryogenic liquid storage vessels and include:

A) A vacuum evacuation port of some type must be installed on the outer vessel allowing a vacuum pump to be connected to pull molecules from the annular space. These are specialized connections capable of pulling down to very low atmospheric (high vacuum) levels without leaking past. On smaller 4L-DOT type vessels this is typically a port and plug assembly that are pulled on using a fixture that allows the plug to be pulled and replaced under vacuum. A larger vacuum diaphragm valve is used with bulk tanks

B) A helium mass-spec leak detector is set up on a slip stream of the vacuum line to allow sampling for helium molecules. The leak detector can only be used effective after vacuum has been pulled down far enough to get a helium reading. If the vacuum will not come then the leak will have to be found by other means and some repair performed prior to performing the full helium mass spec leak investigation. Vacuum valves, vacuum probe tubes and probe tube isolation valves are often replaced prior to performing an investigation due to their propensity for being large leak points. It is also common to break the vacuum seal on a vessel and reseal lift plates where present (including o-ring replacement and vacuum lube addition). Perlite is also added at this point for perlite insulated vessels. It is worth noting that breaking vacuum improperly can be a major source of moisture contamination and can also cause permanent damage to the vessel.

C) The initial leak investigation consists of spraying helium molecules around the outside of the vessel and all penetration points. This process can be painstakingly slow and tedious as a leak can both provide a positive indication and flood the annular space with helium that can take hours (or days) to evacuate. Also- getting a positive reading is only a start. It is often necessary to work through a series of tests where small portions of the vessel seams or other penetrations are masked off to ultimate isolate the leak point. And- repairs requiring welding will likewise require careful breaking of the vacuum, completion of the repair, and then pulling the vacuum back down on the vessel to start testing all over again.

D) Once the outside of a vessel has been determined to be leak-free then helium is added to the inner vessel and some pressure added behind it to look for possible inner leaks. Fortunately, inner leaks are not that common on cryogenic bulk tanks- especially stationary tanks- since they are not subjected to the kind of rough handling that 4L Liquid Cylinder and smaller open top nitrogen dewars are. I say “fortunately” as isolating and repairing inner leaks is most complicated and worthy of another full set of articles.

But what about the differences between Liquid Cylinder and Bulk Tank vacuum investigations?

We’ll hit more on this next.

Friday, September 25, 2009

Cryogenic Bulk Tanks- Vacuum & Leaks (b)

Shortly after posting yesterday’s article I saw an advertisement for cryogenic equipment noting, “We Do Revacs.” And….. so do lots of people. But- Does this include full vacuum investigation and repair?

As mentioned previously, there are very frequent occurrences of people putting a vacuum pump on a tank and pulling the vacuum down within specification limits. Because the vacuum pulls down to where it needs to be the assumption is made that the vessel must be good now. The fly in the ointment here is that a tank with a small leak can easily be pumped on to the point that the vacuum reading is good. This is fairly simple as all you have to do is have a pump that pulls molecules out of the vessels annular space faster than they come in through the leak.

This is very much like a leaky boat. My good friend, John, told the story of an off-shore fishing trip where they struck a piece of driftwood or some other debris and started to take on water. This was particularly problematic since they were catching lots of fish and did not want to quit. So, they turned on the bilge pumps and fortunately were able to pump out water faster than it came in. Returning home the leak grew and they had to pull the plugs in the back of the boat to allow water to flow out. All was OK until they stopped at the boat ramp and jumped out to go get the trailer. Once stopped, the boat sank almost immediately and had to be floated up from the bottom with lift bags.

Interestingly enough, we never talked about it, but the final excess flow might have come from a failure to get the plugs in fast enough once stopped. This has a parallel to cryogenic vessels that will be touched on in a moment.

But, first- If we assume that a cryogenic vessel was originally constructed in a leak tight fashion and this was proven out over years of operation then where did a leak come from? There are several primary sources of vessels leaks:

a) The Vacuum Rupture Disk and/or Lift Plate
b) The Vacuum Probe Tube and/or Probe Tube Isolation Valve
c) The Vacuum Evacuation Valve
d) Piping Penetrations, Doublers and Other External Welds
e) Occasional Inner Leaks

Time, corrosion and/or damage (intentional or otherwise) can cause leaks in each of these areas. Unlike a boat leak, though, it is rare that they are visible with the naked eye. In most cases, these are leaks that have developed very slowly over time and are allowing just a few molecules to seep in little by little. And- as vacuum loss is typically a boiled frog progression (slow and with almost imperceptible progress) it is also difficult to link the leak to any cause or event.

So how do you find the cause and location of a leak?

Helium Mass Spec Leak Detection.

This testing utilizes mass spectrometry equipment specially calibrated for detection of helium molecules along with a vacuum pump to sniff out leaks. Helium is used since the molecules are so small they will travel through the tiniest leaks.

Next we’ll do some review of Helium Mass Spec Testing and the principle causes of leaks in tanks.

Thursday, September 24, 2009

Cryogenic Bulk Tanks- Vacuum and Leaks

"Nature abhors a vacuum."

When conducting cryogenic vessel classes we often discuss the fact that, other than occassional flashes between my ears, natural vacuums do not exist within the earth's atmosphere. Given time and opportunity, all vacuums will draw in molecules to the point that atmospheric balance is restored.
It is no great wonder then that vacuum insulated cryogenic bulk tank and other liquid cryogenic vessels lose their vacuums and related insulation capacity over time. And, when the vacuum is lost, the vessel loses all or the greatest part of its insulating capacity and can no longer protect the liquid from heat resulting in excessive loss of oxygen, argon, or nitrogen liquid product. The mystery (and fun CSI part) of the job comes from determining the how, where, and why of a lost vacuum.
All too often, vessels with bad vacuums are hooked up to a vacuum pump until a good reading is once again achieved. The pump is then disconnected and the vessel returned to use only to find that it is again losing product within days, weeks or months. The process is repeated with the unsurprising recurrence of the problem.
There is another way and we'll discuss it next.....

Friday, September 18, 2009

Oxygen Effects on Wine Production


This article http://www.practicalwinery.com/sepoct09/impact2.htm "IMPACT of oxygen level in wine when bottling" was recently forwarded to me. It provides some specific technical background that might be interesting not only for those in wine production, but also in other industries utilizing nitrogen and CO2 inert gas blanketinig.

Monday, September 14, 2009

Cryogenic Liquid Cylinder Filling- The Venting Dividend


Standard cryogenic liquid cylinder filling procedure for many facilities is to:

1) Connect the source
2) Open the Vent valve; Open the Liquid valve; open the Source
3) Fill by weight
4) Close the Source; Close the Liquid valve; Close the Vent Valve

Others vary Step 4 to:

4+) Close the Source; Close the Liquid valve; Leave the Vent valve open until venting stops (15 minutes to one hour) and then: Close the Vent valve.

The benefits gained from 4+) are significant:

a) High Pressure Liquid Stabilized- When liquid cylinders are filled from a bulk tank with over 40psi there is gas entrapped in the liquid. The higher the pressure of the source tank the more gas is transferred in the liquid. Venting allows this gas to escape instead of crowding up the the liquid cylinders head space building pressure.
b) Hot Liquid Cylinders are Cooled- Liquid Cylinders that sit empty for awhile get warm inside. Allowing the vessel to cool fully prior to closing the vent also reduces the buildup of gas in the head space.
Both of these benefits share the effect of lengthening the flattened, left-hand tail of the pressure building curve. Put another way- Pressure building can be expressed as an accelerating curve. The higher pressure gets the faster the pressure builds steepening the curve to the venting point. The more liquid is allowed to stabilize and cool the longer and flatter the curve.

The net result of all this is that initial time to vent is lengthened and product life is extended.

Friday, September 4, 2009

Sense and Insensibility in Medical Oxygen


Homecare Magazine recently had two articles that might be interesting to those interested in homecare oxygen delivery. The first, "Providing Oxygen Sensibly" http://homecaremag.com/oxygen/select-right-oxygen-technology-200907/ gives some overview of alternative delivery methods, costs, and returns.


The second article, "Vladeck: Home Oxygen Is 'Nothing but Air'" http://homecaremag.com/oxygen/vladeck-congress-reimbursement-cut-20090831/ highlights some of the misperception challenges faced by homecare oxygen providers.


And- Don't forget to mark your calendars for the upcoming MedTrade conference in Atlanta October 12th - 15th. http://www.medtrade.com/ It is one of the few places where you can find so many of the key homecare oxygen manufacturing and service players all together. If you do make it to MedTrade be sure to drop by booth 1131 (West Cryogenics) and say hi.

Friday, August 28, 2009

Liquid Cylinder Reliefs- Getting it Right


You have a relief on a liquid cylinder that is opening like it is supposed to, but won't reseat properly so you decide to replace it. How are you going to determine what relief to replace it with?
a) Look at the relief that is in the vessel and replace it with one just like it?
b) Look up in the owner's manual and see what it says to do?
c) Look at a reference sheet provided by a reputable provider that translates the 4L-DOT ratings and helps specify the "proper" relief, burst disk and presure gauge for your unit.
"A" is an uncomfortably common response. "B" or "C" are the way to go.
Unfortunately- Information on the maximum pressure settings for reliefs and burst disks or pressure ranges is not obvious or plainly stated on cryogenic liquid cylinder data plates. It requires some knowledge of DOT 4L parlance to know that a 4L-292 liquid cylinder will typically have a 350 psi relief and 0-600 psi pressure gauge. The necessity of looking up information is a problem since most users and many distributors don't have handbooks or reference charts readily available at hand. The risk is that an relief and/or burst disk will be installed that is at too high a pressure for the 4L rating of a vessel. This creates a hazard resulting in a possible explosion of the vessel.
If you need help on determining the right relief, burst disk or pressure gauge for your unit drop me a note. I'll be happy to help.

Monday, August 24, 2009

Implosions Are Also A Mess......


There have been several posts in Cryogenic News regarding cryogenic tanks rupturing as a result of over-pressuring. This is important due to the real danger posed by tanks and cylinders that are improperly modified or otherwise malfunctioning.

Implosion is also a very real concern and Wil Ferch (Owner/Principal at Nordstern Associates LLC) has graciously allowed me to reprint his recent article "Don't Let This Happen to You!!" below without endorsement.

Interestingly enough, as I was reading Wil's article I remembered that Dan Ariely (of Predictably Irrational fame) is also a director with The Center for Advanced Hindsight which you can visit at http://web.mit.edu/ariely/www/MIT/thecenter.shtml.

Ideally, employing the lessons shared by Wil and others can help you avoid status as a case study for Dan's group so here it is:

"Don't Let This Happen to You !!!

The industrial gas industry, (producers of liquid oxygen, nitrogen and argon...amongst other products of air), require large site-erected tanks to be built in order to store these liquids for later use. These tanks can range in size up to 2 million gallons or more, and cost millions of dollars. The stored product, like liquid oxygen, exists at about minus 300 degrees Fahrenheit.

In the process of bringing such a newly constructed tank into service, it must first be carefully "cooled-down" such that it can accept incoming cold liquid later. Here is a photo of a typical tank on a representative plant site---> http://gazettextra.com/photos/2008/oct/02/10382/

Nordstern Associates LLC - CASE STUDY # 7

A major global producer of industrial gases, recently "cooled-down" such a tank as part of their commissioning process, utilizing their own qualified personnel and historical procedures. This time, however, things went horribly wrong, and their 450,000 gallon tank went from being a multi-million dollar asset... to nearly scrap metal value, in a fraction of a second ! In the process of cooling down the tank, it vacuum collapsed ! To illustrate the violence, sudden-ness and uncontrolled nature of the collapse, here is a YouTube film clip showing a similar ( this time, on purpose ! ) tank collapse of a railway tanker.---> http://www.liveleak.com/view?i=72e_1208694365&p=1

Also, when such a flat-bottom tank vacuum collapses, it may implode the top and side walls, and also start to "lift" the center of the flat floor. See here of what such damage looks like in yet another example ( once the web page is opened...move down to title, " Plastic bag vs. Storage tank" for photos and text.)----> http://www.driedger.ca/dp-1/Dirty%20Pictures%201.html

After the damaged tank was repaired, Wil Ferch of Nordstern Associates LLC was enlisted to provide both a revised cool-down procedure, and on-site supervision of the new attempt to cool-down the tank. Result?--> a perfect cool-down with no damage ! Wil Ferch, principal at Nordstern Associates had over 20 years of experience cooling down these types of tanks with a 100% recorded success rate throughout his career !

So....don't let this happen to you !

The industrial gas business has lost much in the way of retained skill sets and nuance-driven knowledge with long-term staff changes. Enlist people who have the training and knowledge to do this correctly. Call upon Nordstern Associates, LLC.

Contact--> Wil Ferch, principal at Nordstern Associates, LLC and let us discuss this.... or other support needs. ( ferch.wil@gmail.com .... business tel : +1 716 983 4089, alt tel: +1 716 662 7173). "

Sunday, August 23, 2009

Predictably Irrational & Cryogenics



One of my favorite writers is Dan Ariely of "Predictably Irrational" (both book and blog) fame. In his most recent blog at http://www.predictablyirrational.com/ ("Are We More Rational Than Our Fellow Animals?" Dan uncovers some of the advantages we humans enjoy through possession of a neocortex. According to Dan, this is "the most recently evolved part of the brain and the center of higher mental functions" and "it’s thanks to our neocortex that we are able to plan for the future." The gist of his article is that our ability to think at a higher level and plan does not always add up to brilliantly rational actions benefitting our own best interest.

Witness the 4L-DOT cryogenic liquid cylinder shown above with both the safety relief and burst disk plugged.


What is the rational solution for a relief that continues to vent and make irritating noise? Someone apparently figured removing the relief and replacing it with a plug would do the job.


And then what do you do when the pressure builds so high that it blows the burst disk and pressure is lost? One solution is apparently to remove the blown burst disk safety and replace it with a plug.


OK- so maybe the planning capacity of the neocortex wasn't fully developed in this case....... as witnessed by the ultimate result of an overpressurized (exploded) liquid cylinder. The most fortunate part of all of this is the fact it happened at 3:00 a.m. which is about the only time where someone would not be in the lab to get hurt.


A more in depth article on this incident can be found at http://ucih.ucdavis.edu/docs/chemistry_301a.pdf. It is great reading for anyone open to learning from the mistakes of others.

Lifetime Learning

"......but tho' an old man, I am but a young gardener." - Thomas Jefferson to Charles Willson Peale, August 20, 1811

Jefferson's information request sent to one of his time's most noted gardeners speaks volumes. The fact is that, for all the things Jefferson did, it is quite fair to say his real lifetime hobby was learning.

As a model of "the more I learn, the more I realize I don't know" he personified one of the greatest joys there is by constantly pursuing new endeavours from architecture and design to philosophy, education, gardening and more.

Why do I mention this?

This is going to be another of those great weeks where I get to "learn as I teach" with at least three days at client sites delving into operations and working together towards continuous improvement. Not to mention a weekend of gardening, energy conservation, farmer's markets and Saturday morning cooking class........ (a special thanks to Monica Pope at T'Apia in Houston).

And herein also rests the beauty of the cryogenics and gases industry where there is so much to learn and so many really neat people to learn it with......