Showing posts with label vacuum rupture disk. Show all posts
Showing posts with label vacuum rupture disk. Show all posts

Friday, September 25, 2009

Cryogenic Bulk Tanks- Vacuum & Leaks (b)

Shortly after posting yesterday’s article I saw an advertisement for cryogenic equipment noting, “We Do Revacs.” And….. so do lots of people. But- Does this include full vacuum investigation and repair?

As mentioned previously, there are very frequent occurrences of people putting a vacuum pump on a tank and pulling the vacuum down within specification limits. Because the vacuum pulls down to where it needs to be the assumption is made that the vessel must be good now. The fly in the ointment here is that a tank with a small leak can easily be pumped on to the point that the vacuum reading is good. This is fairly simple as all you have to do is have a pump that pulls molecules out of the vessels annular space faster than they come in through the leak.

This is very much like a leaky boat. My good friend, John, told the story of an off-shore fishing trip where they struck a piece of driftwood or some other debris and started to take on water. This was particularly problematic since they were catching lots of fish and did not want to quit. So, they turned on the bilge pumps and fortunately were able to pump out water faster than it came in. Returning home the leak grew and they had to pull the plugs in the back of the boat to allow water to flow out. All was OK until they stopped at the boat ramp and jumped out to go get the trailer. Once stopped, the boat sank almost immediately and had to be floated up from the bottom with lift bags.

Interestingly enough, we never talked about it, but the final excess flow might have come from a failure to get the plugs in fast enough once stopped. This has a parallel to cryogenic vessels that will be touched on in a moment.

But, first- If we assume that a cryogenic vessel was originally constructed in a leak tight fashion and this was proven out over years of operation then where did a leak come from? There are several primary sources of vessels leaks:

a) The Vacuum Rupture Disk and/or Lift Plate
b) The Vacuum Probe Tube and/or Probe Tube Isolation Valve
c) The Vacuum Evacuation Valve
d) Piping Penetrations, Doublers and Other External Welds
e) Occasional Inner Leaks

Time, corrosion and/or damage (intentional or otherwise) can cause leaks in each of these areas. Unlike a boat leak, though, it is rare that they are visible with the naked eye. In most cases, these are leaks that have developed very slowly over time and are allowing just a few molecules to seep in little by little. And- as vacuum loss is typically a boiled frog progression (slow and with almost imperceptible progress) it is also difficult to link the leak to any cause or event.

So how do you find the cause and location of a leak?

Helium Mass Spec Leak Detection.

This testing utilizes mass spectrometry equipment specially calibrated for detection of helium molecules along with a vacuum pump to sniff out leaks. Helium is used since the molecules are so small they will travel through the tiniest leaks.

Next we’ll do some review of Helium Mass Spec Testing and the principle causes of leaks in tanks.

Thursday, September 24, 2009

Cryogenic Bulk Tanks- Vacuum and Leaks

"Nature abhors a vacuum."

When conducting cryogenic vessel classes we often discuss the fact that, other than occassional flashes between my ears, natural vacuums do not exist within the earth's atmosphere. Given time and opportunity, all vacuums will draw in molecules to the point that atmospheric balance is restored.
It is no great wonder then that vacuum insulated cryogenic bulk tank and other liquid cryogenic vessels lose their vacuums and related insulation capacity over time. And, when the vacuum is lost, the vessel loses all or the greatest part of its insulating capacity and can no longer protect the liquid from heat resulting in excessive loss of oxygen, argon, or nitrogen liquid product. The mystery (and fun CSI part) of the job comes from determining the how, where, and why of a lost vacuum.
All too often, vessels with bad vacuums are hooked up to a vacuum pump until a good reading is once again achieved. The pump is then disconnected and the vessel returned to use only to find that it is again losing product within days, weeks or months. The process is repeated with the unsurprising recurrence of the problem.
There is another way and we'll discuss it next.....

Tuesday, February 10, 2009

Vacuum Rupture Disk- Blown B


A client called upset that they’d just received 20 liquid cylinders back from rehab and now had 18 in the yard “bad.” They wanted immediate attention and got it. Two things were obvious on arrival. The first was that there were no DOT-4L repair “K” tags on the vessels indicating right away that we’d never seen the vessels in question. Number two, and most upsetting to the client, was the very apparent indication that someone had intentionally punctured the rupture disk on 18 of the 20 liquid cylinders. This was obvious as the protective disk covers were missing and the disks were blown “in” instead of “out.”

The purpose of vacuum rupture disks for cryogenic tanks and liquid cylinders is to prevent rupturing of the outer vessel which has no pressure rating. Vacuum rupture disks are very thin, concave and surrounded by knife edges which are lined up just over the surface. A very low pressure build up in the annular space of an oxygen, nitrogen, argon or carbon dioxide cryogenic tank will cause the disk to protrude against the cutting edges and rupture allowing free flow of the gas to atmosphere. So- any CSI investigator who sees the disk blown out can readily tell that a vessel with a disk blown “out” probably has some type of inner leak.

A disk that is blown “in” indicates a leak occurred in the disk and the vacuum in the annulus sucked atmosphere from outside pulling the disk in. There are slip-on plastic protective covers installed over most disks to prevent damage that would cause a leak. Many manufacturers and service companies also install a warning between the cover and disk noting that removal or tampering will void any warranty of the vessel. This cover helps protect the disk from welding or cutting sparks and corrosion that could cause a vacuum space leak in the cryogenic tank.

When there is a good vacuum on a tank then rupturing the disk will cause a great whoosh of flow into the annulus. It is an all too common occurrence for vandals to remove the covers and puncture the disks. Whether their intent is malicious or just for entertainment the result is the same. The liquid cylinder now has no vacuum and will have to be sent in for a rather expensive repair.

Next, we’ll talk about responsibility and how cryogenic liquid suppliers can save hundreds of dollars by training their drivers to be alert to damage and consistent in documenting it on site.

Monday, February 9, 2009

Vacuum Rupture Disk- Blown A




Which cryogenic liquid cylinder in this photo still has a vacuum?

Actually, the only thing we can tell from this photo is that the bottom two do not have any vacuum since their vacuum rupture disks are both blown. The top liquid cylinder might or might not, but this can only be determined through testing.

Vacuum rupture disks are installed on cryogenic liquid cylinders and tanks to protect the outer vessel from rupturing. The inner vessel of a cryogenic tank or liquid cylinder is typically designed as a pressure vessel. Both resetting relief devices and one time rupture disks (head safeties) are usually installed to prevent the inner vessel from over-pressuring and exploding. The outer vessel is only a protective skin and carries no pressure rating. A leak from the inner vessel into the annulus causes pressure to build against the outer vessel. Vacuum rupture disks or vacuum lift plates are installed on outer vessels to allow them the vent almost immediately in the event pressure begins to form in the annulus.

The next things we’d like to know are what might be determined from “how” the disk blew and “who” might should bear the cost of repair.