Sunday, July 5, 2009

Simple Set Screw Solution- Shrink Seal

Today’s suggestion: Shrink Seal the set screws on your cryogenic liquid cylinder pressure building and economizer regulators.

There has been a lot of emphasis in this post on the difference between flow and pressure. The primary focus of discussion has been to try and clarify the fact that higher pressure does not equate to higher flow. Point: Cranking up the pressure builder setting on your liquid oxygen, nitrogen or argon 4L-DOT liquid cylinders does little or nothing to provide higher flow and can cause a number of negatives……..

- Out of Balance Economizers,
- Broken PB Regulators,
- Excessive Venting and more.

Solution- Leave the set screw alone. The odds of this happening- It depends.

Make it harder to mess with the screw and you might find an ounce of prevention to be worth a pound of cure. Where necessary- Create consequences for tampering with pressure builders and you might deter even more tinkering.

Oh, and yes- West Cryogenics has been doing this for years and sells both shrink seal material and heat guns.

www.westcryogenics.com

Sunday, May 10, 2009

4L DOT Cryogenic Liquid Cylinder Excessive Venting

The very best training sessions are those that get really conversational. Discussing case studies and reviewing alternative strategies are the root of “I learn as I teach.” One question asked this week was, “Do clients know to turn on their pressure builder isolation valves as soon as they receive their liquid cylinders?” The conclusion was that all too many users don’t know not to turn on the pressure builders on receipt.

A somewhat difficult issue applies when a system is set up with a primary and secondary bank of liquid cylinders tied into an automatic switch over control system. When the online bank of liquid oxygen, nitrogen or argon liquid cylinders runs low the system automatically switches over to the other bank. Since this could happen at almost any time the pressure builder(PB) valves have to remain open on the reserve bank.

If, though, it is known that the reserve bank will not go on line for several days then it is advisable to not turn on the PB valves right away. This is especially true if you have a Friday delivery to a facility that does not operate over the weekend. Just waiting until Monday to turn on the PB valve can add many days to the life of the liquid cylinders and greatly reduce product wasted to venting.