Thursday, April 30, 2009

Venting Cryogenic Vessels- Is Product Lost?


“OK- So you recommend venting cryogenic liquid cylinders and portable vessels down “fully” after filling. But- Doesn’t this waste product?”

Answer: Define “product.”

If the “product” you are referencing is liquid oxygen, nitrogen or argon then No. Venting off gas created during the fill process will actually help preserve liquid in your 4L DOT Liquid Cylinder, Medical Liquid Oxygen delivery vessel or other portable container. The fact is that the gas in the vessel that you would be venting off has already been lost and is no longer liquid product.

Remember- Pressure building tends to be an accelerating curve the higher the pressure in you vessel the shorter the time before you start venting. If you vent down all the way back to right at zero then you stabilize the liquid in your tank moving you back away from the venting time point. You also remove gas which is by definition hotter than liquid. Getting this gas out also helps remove energy that raises the temperature of your liquid product. As a last point- A filled vessel with pressure on it also has a potential to push liquid into the venting system which will boil off and create pressure.

If the “product” you are referencing is gaseous oxygen, nitrogen or argon then you might be wasting a little product. BUT- this is only true if you plan to immediately use the vessel and you will be able to harvest the oxygen, nitrogen or argon gas right away for cutting, purging or some other use. If you are not using it right away then leaving gas pressure in the vessel will just lead to faster venting and the product will be lost anyhow. You will also lose additional gas created by liquid boiling off sooner than it needed to.

Wednesday, April 29, 2009

Overfilling Portable Cryogenic Liquid Vessels

There are several negative consequences that can result from overfilling portable cryogenic liquid vessels used for transport or delivery of liquid oxygen, nitrogen or argon. While there are also concerns with 4L-DOT liquid cylinders and stationary bulk tanks this article is more focused on horizontal vessels from approximately 119 gallons up that are used for medical oxygen delivery, construction and demolition or other portable applications.

If you fill portable horizontal cryogenic tanks do you always stay in close attendance while filling?Do you use the Full Trycock as your indicator for when to stop? Or do you have a “full” mark on your liquid level indicator to tell you when to stop filling that is well below the point that liquid would come out the vent?

If you answered “yes” to these questions then you are less likely to have some of the problems that are common with overfilling.

First, let’s note that most portable horizontal cryogenic liquid vessels are fitting with a Full Trycock. This line and the vent are to be fully open when transfilling liquid into the portable vessel. The trycock and vent lines run into the top of the vessel. The Trycock line is lower inside the vessel than the vent so that liquid will come out the trycock before reaching the vent. Shutting off the fill as soon as liquid starts to come out the trycock reduces the incidence of liquid getting all the way up to the fill line.

It is not uncommon to hear of situations where the trycock was not used or the liquid source was not shut off quickly enough. Liquid was then allowed to flow out the vent. This can result in:

a) Liquid running up through a roof or side vent and ruining paint or cracking the metal or windshield of a vehicle in hot weather.
b) Uncontrolled liquid oxygen flow running to areas which will be saturated increasing fire risks;
c) Liquid being trapped in the vent line when the fill line and vent line are closed with inadequate head space left in the vessel.

Incident “C” is a common reason for vessels building excessive pressure. Liquid trapped in the line will rapidly vaporize creating pressure in the vessel and causing it to vent excessively. It can also result in blown head safety rupture disks. Users often mistake this overfilling for a vacuum related problem as the net result (over pressuring) is very similar.

A lot of discussion occurs in this post about the importance of fully venting cryogenic liquid vessels when they are filled. This means that after shutting off the liquid fill source you need to vent until there is no evident positive air flow from the vent line prior to closing it. There are few more important things that can be done to help prevent premature and excessive venting of cryogenic liquid vessels. Venting will also help correct some of the ills of over filling and hot filling.

But- Is product wasted when we vent fully?

Tuesday, April 28, 2009

Quality- What is it?

“Trifles make perfection and perfection is no trifle.”
- Michelangelo

Last week provided an opportunity for one of the more pleasant dinner evenings ever. Besides the general joy of being with a large group of gas sales and marketing executives there was also a terrific discussion on the mid-90’s Austin/ Dallas/ San Antonio semiconductor surge. For those less familiar, this was the when the electronics Third Coast was flourishing with the construction of many new fabs for companies like AMD, MOTOROLA, TI, SEMATECH, HITACHI, ST MICROELECTRONICS, and NATIONAL SEMICONDUCTOR. Of equal import for many of us was the great influx of suppliers to the industry such as Applied Materials and Tokyo Electron not to mention the dozens of specialty mechanical and cleanroom contractors, chemical suppliers, and analytical services.

An almost cliché, but largely unmet maxim is: “People don’t buy because they understand. They buy because they feel understood.” This is largely unmet mostly because developing a true understanding of client needs and then actually meeting or exceeding them can be hard work.

Inherent to success in the electronics market rush was the ability to meet the stringent quality demands of the industry. Those of us who prospered found opportunities to go beyond keeping up and actually become drivers of the standards expected for service providers. First, though, we had to come to grips with what was actually needed and what could be done. For many of us, the leap from our normal life to Semiconductor-Grade was a jolt.

Dan Driessen formed Ultrapure & Industrial Services as a division of Driessen Culligan to develop a team focused on the needs and opportunities inherent in the growing markets for semiconductor, electronics and medical device manufacturing. As a novel first step in truly understanding client needs the Ultrapure group set up a series of roundtable discussions with some of the area companies most recognized for formal quality. These included 3-M, Motorola, Sematech, AMD, Huntsman Chemical and The UT Microelectronics Research Center. Over the course of three separate monthly round table events these clients shared their definitions of quality, their perceptions of the industry’s specific needs and the gaps Ultrapure would need to close to become a recognized player.

What these clients had to say definitely upset our homeostasis and created huge doubts regarding both the ability to perform as needed and the ultimate profit to be gained in consideration of costs. Yet, the decision was made in short order to move forward. The next several years proved to be both challenging and rewarding beyond expectations. And a lot of lessons were learned that will benefit us and those we have the opportunity to serve for the rest of our lives.

Last week’s dinner brought up a lot of great memories. It especially helped with connecting the dots to the needs of clients using cryogenic vessels and their service support needs. CryoNews is intended to help meet those needs for both suppliers and users. The underlying themes of all articles in this post are Quality and Best Practices as they relate to meeting Producer, Distributer and User needs and eliminating waste. Your suggestions related to topics that will advance this mission are always appreciated.

Monday, April 27, 2009

Spec Gas- The Eyes Have It

The gases business has an incredibly broad reach into industry and medicine. Visits to gas producer web sites can be real eye openers. A little blip viewed yesterday referenced perfluoropropane. Do you already know all about it and what it is used for?

Would you believe it is used as a tool in pneumatic retinopexy?

This is a surgery used for repair of some retinal detachments. According to http://www.webmd.com/, “It uses a bubble of gas to push the retina against the wall of the eye, allowing fluid to be pumped out from beneath the retina. It is usually an outpatient procedure done with local anesthesia.” Full healing and recovery takes weeks, but the gas is eventually absorbed into the body.

And why do we care?

Mostly, we care from a big picture stand point. Specifically, most of us are widely unaware of the amount of specialty gas products produced by U.S. manufacturers and shipped all over the world. Take a peek sometime and you’ll find an amazing volume of specifications for these products related to purity and product consistency. This applies to both Healthcare and Industrial applications where tiny variables can make a huge difference. Personally, I’m thankful for the chemists, scientists, engineers and techs who work quietly everyday in relative obscurity doing things that make our lives better.

Friday, April 24, 2009

Cryogenic Liquid Cylinder Operation- Part 3- Pressure Building System

The April 16th article http://cryonews.blogspot.com/2009/04/cryogenic-liquid-cylinder-operation_16.html discussed why it is necessary to have a gas use coil that pulls liquid from the bottom of a 4L DOT Cryogenic Liquid Cylinder and vaporize it for gas use supply.

And- It was noted that a pressure building system is needed to help maintain pressure within a specified operating range. So, how does the pressure building system work?

Liquid cylinders equipped with gas use coils also have another set of coils brazed to the inside skin of the outer jacket. Just like the gas use coils- the pressure building coils pull liquid from the bottom of the liquid cylinder and vaporize it. Vaporization happens by exposing the liquid to temperatures above its boiling point.

Unlike the Gas Use system, the Pressure Building system returns vaporized gas back to the head space of the liquid cylinders. Crowding gas molecules into this head space raises the pressure of the liquid cylinder. The pressure building regulator controls the flow of liquid into the coils and stops the flow of gas back into the head space.
It is important to note, though, that this does not stop pressure from building. Once pressure is raised on a liquid cylinder and warmer air is introduced into the top of it normal evaporation of liquid nitrogen, argon or oxygen will increase. Be sure that the valves feeding pressure building regulators are closed if the vessel is not going to be used over night or over a several day period. Venting of pressure and release of hotter air can also help minimize product lost due to normal evaporation.

Monday, April 20, 2009

Cryogenic Liquid Cylinder Operation- Part 2D- Gas Withdrawal

Is there a limit to how much liquid can be vaporized by the internal gas use coil in a standard 160liter to 200liter 4L DOT cryogenic liquid cylinder?

Yes. And that limit ranges between 300-400 standard cubic feet per hour (SCFH) depending on the make/model of the liquid cylinder, the gas in question, the external humidity and outside temperature. Direct exposure to the sun will also increase gas flow. This rating is for an 8 hour period and it diminishes rapidly with excessive flow or time.

Why does this matter?

The failure to use this information is one of the biggest contributors to dissatisfaction with liquid cylinder operations. Users who start with high pressure cylinders and “move up” to liquid cylinders are not accustomed to limits on how much gas they can draw. This is particularly true for operators of large tip cutting torches and oxygen lances. Drawn by the relative convenience and weight of liquid cylinders they do not realize that their operation requiring 700 to 1500 scfh gas flow simply cannot be supported by one or two liquid cylinders linked together with only internal vaporizing coils.

What happens if flow is too high?

Very simply- if the liquid is not vaporized then it comes out as liquid. This can be disastrous for many operations unable to withstand extremely cold cryogenic liquid temperatures. For instance, a carbon steel tank that is being purged with nitrogen gas can easily split when sprayed directly with liquid nitrogen.

Is there a way to get more gas flow from a cryogenic liquid cylinder?

Yes, absolutely. All you have to do is add downstream ambient vaporization. Remember, though, not all vaporization is the same. Some vaporization packages for liquid cylinders (ex- Dragons) take into account connecting vent line connections to balance pressure and withdrawal rates. A vaporizer added straight on to the gas use line will be more limited than one tied to the liquid line. The liquid line connection is larger internally and has less flow restriction allowing for more gross flow of molecules. Withdrawing product from the liquid connection also prevents chilling of the outer vessel skin enhancing the ability of the pressure building coil to produce gas that replenishes the head space.

Pressure building coil?

More next time…….

Saturday, April 18, 2009

Homecare Medical Oxygen- Fuzzy Math

The Medicare Benefits related to oxygen were changed three years ago limiting collection of rental for respiratory oxygen equipment to 36 months for individual patients. There are a number of articles and talks discussing the direct impact of this new guideline on oxygen providers. And there is some fuzzy math being used. As mentioned by an old boss, figures lie……

It is purported by the Office of the Inspector General that 22% of Medicare patients receive care for over 36 months. Does this mean then that 22% of oxygen rentals just went away at the36 month point?

This is not likely.

Medicare does not account for 100% of rental billing. Even if it did, the only way January could account for 22% instant reduction would be for providers to have set up no new accounts since January 2006. Not.........

Yes. The Medicare guidelines are most certainly having a big impact on oxygen providers. But- there are homecare oxygen companies who continue to grow and very many who do not have business plans built around reliance on Medicare.